:TIMEr:TEMPlet:OBJect
Syntax
:TIMEr:TEMPlet:OBJect {V|C},{
:TIMEr:TEMPlet:OBJect? [MINimum|MAXimum]
Description
Select the editing object of the templet and set the current or voltage.
Query the editing object of the templet currently selected as well as the
corresponding current or voltage.
Parameter
Name
Type
Range
Default
{V|C}
Discrete
V|C
V
Real
Voltage or current range of the
channel currently selected
0
Explanation
When V is selected, the editing object is set to voltage and
the current value; when C is selected, the editing object is set to current and
Return Format
The query returns the editing object currently selected and the corresponding
voltage or current value (separated by comma), for example, V,2.0000. Wherein, V
denotes that the editing object currently selected is voltage; 2.0000 denotes that
the current currently set is 2A.
Example
:TIME:TEMP:OBJ V,2 /*Set the editing object of the templet to voltage and set the
current to 2A*/
:TIME:TEMP:OBJ? /*Query the editing object of the templet as well as the
corresponding current or voltage and the query returns
V,2.0000*/