:MONItor:VOLTage:CONDition

Syntax

:MONItor:VOLTage:CONDition {V|NONE},{AND|OR|NONE}
:MONItor:VOLTage:CONDition?

Description

Set the voltage monitor condition of the monitor (the current channel).
Query the voltage monitor condition of the monitor (the current channel).

Parameter

Name

Type

Range

Default

{V|NONE}

Discrete

V|NONE

NONE

{AND|OR|NONE}

Discrete

AND|OR|NONE

NONE

Explanation

 You can set the voltage monitor condition to "V" (>voltage)

or "NONE". "NONE" means do not monitor the voltage.

 The actual monitor condition is the logic combination of the voltage, current

and power.

 You can send the

:MONItor:VOLTage[:VALue]

command to set the voltage

monitor value.

Return Format

The query returns the voltage monitor condition and logic relation separated by

comma, for example,

Example

:MONI:VOLT:COND

channel) to "

:MONI:VOLT:COND? /*Query the current voltage monitor condition (the

current channel) and the query returns

Related

Commands

:MONItor:CURRent:CONDition
:MONItor:CURRent[:VALue]
:MONItor:POWER:CONDition
:MONItor:POWER[:VALue]
:MONItor:VOLTage[:VALue]

This manual is related to the following products: