beautypg.com

Source[]]:voltage:protection:clear, Source[]]:voltage:protection:clear -93 – RIGOL DP832A User Manual

Page 117

background image

Chapter 2 Command System

RIGOL

DP800 Programming Guide

2-93

[:SOURce[]]:VOLTage:PROTection:CLEar

Syntax

[:SOURce[]]:VOLTage:PROTection:CLEar

Description

Clear the circuit and label of the OVP occurred on the corresponding channel and

turn on the output of the corresponding channel.

Parameter

Name

Type

Range

Default

[]

Integer

1|2|3

1

Explanation

 You can send the

[:SOURce[]]:VOLTage:PROTection:TRIPped?

command

to query whether OVP occurred on the specified channel.

 Before executing the command, make sure that the reason that causes the

OVP on the specified channel is cleared (you can decrease the output voltage

to be below the OVP value or increase the OVP value to be greater than the

output voltage); otherwise, the command is invalid. Executing this command

will clear the circuit and label of the OVP occurred on the specified channel and

turn on the output of the corresponding channel.

 When [:SOURce[]] or [] is omitted, the system clears the circuit and

label of the OVP occurred on the current channel.

 You can send the

:OUTPut:OVP:CLEAR

command to only clear the label of the

OVP occurred on the specified channel.

Example

:VOLT:PROT:TRIP? /*Query whether OCP occurred on the current channel

and the query returns YES*/

(Operation: decrease the output voltage to be below the OVP value or increase the

OVP value to be greater than the output voltage)
:VOLT:PROT:CLE /*Clear the circuit and label of the OVP occurred on the

current channel*/

:VOLT:PROT:TRIP? /*Query whether OVP occurred on the current channel

and the query returns NO*/

Related

Commands

[:SOURce[]]:VOLTage:PROTection:TRIPped?
:OUTPut:OVP:CLEAR

This manual is related to the following products: