Source[]]:current[:level]:triggered[:amplitude – RIGOL DP832A User Manual
Page 109
RIGOL
DP800 Programming Guide
2-85
[:SOURce[
Syntax
[:SOURce[
[:SOURce[
Description
Set the trigger current of the specified channel.
Query the trigger current of the specified channel.
Parameter
Name
Type
Range
Default
[
Integer
1|2|3
1
Real
0 to the maximum current
of the specified channel
0.1A
Explanation
When [:SOURce[
parameter of the channel currently selected.
When the trigger source (
) is set to "IMM" (immediate trigger), the system executes
a complete trigger operation (the voltage/current of the specified channel change
to the trigger voltage/current currently set immediately) when executing
When the trigger source (
) is set to "BUS" (bus trigger, namely software trigger),
the system generates a trigger by executing the
command to initialize the trigger system.
Then, the power supply executes a trigger operation (the voltage/current of the
specified channel change to the trigger voltage/current currently set) after the
specified delay time (if the delay time is set,
).
command to set the trigger current
of the specified channel.
Return
Format
The query returns the trigger current of the specified channel, for example, 1.0000A.
Example
:CURR:TRIG 1 /*Set the trigger current of the current channel to 1A*/
:CURR:TRIG? /*Query the trigger current of the current channel and the query
returns 1.0000A*/
Related
Commands
:TRIGger:IN:IMMEdiate
*TRG
:TRIGger[:SEQuence]:DELay