beautypg.com

Output:ovp:alar, Output:ovp:ques, Output:ovp:alar? -58 – RIGOL DP832A User Manual

Page 82: Output:ovp:ques? -58, Output:ovp:alar? :output:ovp:ques

background image

RIGOL

Chapter 2 Command System

2-58

DP800 Programming Guide

:OUTPut:OVP:ALAR?

:OUTPut:OVP:QUES?

Syntax

:OUTPut:OVP:ALAR? [CH1|CH2|CH3]

:OUTPut:OVP:QUES? [CH1|CH2|CH3]

Description

Query whether OVP occurred on the specified channel.

Parameter

Name

Type

Range

Default

[CH1|CH2|CH3]

Discrete

CH1|CH2|CH3

None

Explanation

 Overvoltage protection (OVP) refers to that the output turns off automatically

when the actual output voltage of the channel exceeds the OVP value.

 When [CH1|CH2|CH3] is omitted, the system queries whether OVP occurred on

the current channel.

 You can send the

:OUTPut:OVP:CLEAR

command to clear the OVP occurred on

the specified channel.

Return Format

The query returns YES or NO.

Example

:OUTP:OVP:ALAR? CH1
:OUTP:OVP:QUES? CH1 /*Query whether OVP occurred on CH1 and the query

returns YES*/

Related

Command

:OUTPut:OVP:CLEAR

This manual is related to the following products: