beautypg.com

Delay:stop, Delay:stop -17 – RIGOL DP832A User Manual

Page 41

background image

Chapter 2 Command System

RIGOL

DP800 Programming Guide

2-17

:DELAY:STOP

Syntax

:DELAY:STOP {NONE|V|C|P}[,|MINimum|MAXimum]
:DELAY:STOP? [MINimum|MAXimum]

Description

Set the stop condition of the delayer.
Query the stop condition of the delayer.

Parameter

Name

Type

Range

Default

{NONE|V|

C|P}

Discrete

NONE|V|C|P

NONE

Real

0 to the maximum

voltage/current/power of the

current channel

0V/0A/0W

Explanation

 The power supply monitors the output voltage, current and power during delay

output. Use this command to set a stop condition and the delay output stops

when state that fulfills this condition is detected.

 "NONE", "V" "C", "P" can set the stop condition to

"None", "Volt", "Curr", "Power"

respectively.

is used to set the voltage, current or power of the stop condition and

when it is omitted, this command is used to select the stop condition.

Return Format

The query returns NONE or "stop condition,value", for example, >V,8.000.

Example

:DELAY:STOP >V,8 /*Set the stop condition of the delayer to ">8V"*/
:DELAY:STOP? /*Query the current stop condition of the delayer and the

query returns >V,8.000*/

This manual is related to the following products: