DP800 Programming Guide

:TRIGger:OUT:DUTY

Syntax

:TRIGger:OUT:DUTY [D0|D1|D2|D3,]
:TRIGger:OUT:DUTY? [D0|D1|D2|D3]

Description

Set the duty cycle of the square waveform of the trigger output on the specified

data line.
Query the duty cycle of the square waveform of the trigger output on the specified

data line.

Parameter

Name

Type

Range

Default

[D0|D1|D2|D3]

Discrete

D0|D1|D2|D3

D0

Integer

10 to 90

50

Explanation

 Duty cycle is defined as the percentage that the high level takes up within a

whole square waveform period.

 If [D0|D1|D2|D3] is omitted, the command sets the duty cycle of the square

waveform of the trigger output on the data line currently selected.

Return Format

The query returns an integer from 10 to 90.

Example

:TRIG:OUT:DUTY D1,60 /*Set the duty cycle of the square waveform of the

trigger output on D1 to 60%*/

:TRIG:OUT:DUTY? D1 /*Query the duty cycle of the square waveform of the

trigger output on D1 and the query returns 60*/