beautypg.com

Timer:templet:minvalue, Timer:templet:minvalue -137 – RIGOL DP832A User Manual

Page 161

background image

Chapter 2 Command System

RIGOL

DP800 Programming Guide

2-137

:TIMEr:TEMPlet:MINValue

Syntax

:TIMEr:TEMPlet:MINValue {|MINimum|MAXimum}
:TIMEr:TEMPlet:MINValue? [MINimum|MAXimum]

Description

Set the minimum voltage or current of the templet currently selected.
Query the minimum voltage or current of the templet currently selected.

Parameter

Name

Type

Range

Default

Real

Voltage or current range of the

channel currently selected

0

Explanation

 This command sets the minimum voltage or current (depend on

the

:TIMEr:TEMPlet:OBJect

command). When the editing object is voltage, this

command sets the minimum voltage; when the editing object is current, this

command sets the minimum current.

 When the Pulse templet is used, this command is used to set the low level.

Return Format

The query returns the minimum voltage or current of the templet currently selected,

for example, 0.100 or 0.1000.

Example

:TIME:TEMP:OBJ C,1.5 /*Set the current editing object to current and set the

voltage to 1.5V*/

:TIME:TEMP:MINV 0.1 /*Set the minimum current of the templet currently

selected to 0.1A*/

:TIME:TEMP:MINV? /*Query the minimum current of the templet currently

selected and the query returns 0.1000*/

Related

Commands

:TIMEr:TEMPlet:OBJect

:TIMEr:TEMPlet:SELect

This manual is related to the following products: