Timer:templet:symmetry, Timer:templet:width, Timer:templet:symmetry -141 – RIGOL DP832A User Manual
Page 165: Timer:templet:width -141
RIGOL
DP800 Programming Guide
2-141
:TIMEr:TEMPlet:SYMMetry
Syntax
:TIMEr:TEMPlet:SYMMetry
:TIMEr:TEMPlet:SYMMetry?
Description
Set the symmetry of RAMP.
Query the symmetry of RAMP.
Parameter
Name
Type
Range
Default
Integer
0 to 100
50
Explanation
Symmetry refers to the ratio of the duration of the rising edge within a period to the
whole period.
Return Format
The query returns an integer from 0 to 100, for example, 60.
Example
:TIME:TEMP:SYMM 60 /*Set the symmetry of RAMP to 60%*/
:TIME:TEMP:SYMM? /*Query the symmetry of RAMP and the query returns
60*/
:TIMEr:TEMPlet:WIDTh
Syntax
:TIMEr:TEMPlet:WIDTh
:TIMEr:TEMPlet:WIDTh?
Description
Set the positive pulse width of Pulse.
Query the positive pulse width of Pulse.
Parameter
Name
Type
Range
Default
Integer
1s to 99998s
5s
Explanation
Pulse width refers to the duration of high level within a period.
The actual range available of
). The actual range available is from 1s to (period-1s).
Return Format
The query returns an integer, for example, 14.
Example
:TIME:TEMP:WIDT 14 /*Set the pulse width of Pulse to 14s*/
:TIME:TEMP:WIDT? /*Query the pulse width of Pulse and the query returns
14*/
Related
Command