:TRIGger:OUT:PERIod
Syntax
:TRIGger:OUT:PERIod [D0|D1|D2|D3,]
:TRIGger:OUT:PERIod? [D0|D1|D2|D3]
Description
Set the period of the square waveform of the trigger output on the specified data
line.
Query the period of the square waveform of the trigger output on the specified data
line.
Parameter
Name
Type
Range
Default
[D0|D1|D2|D3]
Discrete
D0|D1|D2|D3
D0
Real
0.000100s to 2.500000s
1s
Explanation
If [D0|D1|D2|D3] is omitted, the command sets the period of the square
waveform of the trigger output on the data line currently selected.
The units supported by
Return Format
The query returns a value from 0.000100 to 2.500000.
Example
:TRIG:OUT:PERI D1,0.005 /*Set the period of the square waveform of the trigger
output on D1 to 5ms*/
:TRIG:OUT:PERI? D1 /*Query the period of the square waveform of the
trigger output on D1 and the query returns 0.005000*/