beautypg.com

Trigger:out:period, Trigger:out:period -154 – RIGOL DP832A User Manual

Page 178

background image

RIGOL

Chapter 2 Command System

2-154

DP800 Programming Guide

:TRIGger:OUT:PERIod

Syntax

:TRIGger:OUT:PERIod [D0|D1|D2|D3,]
:TRIGger:OUT:PERIod? [D0|D1|D2|D3]

Description

Set the period of the square waveform of the trigger output on the specified data

line.
Query the period of the square waveform of the trigger output on the specified data

line.

Parameter

Name

Type

Range

Default

[D0|D1|D2|D3]

Discrete

D0|D1|D2|D3

D0

Real

0.000100s to 2.500000s

1s

Explanation

 If [D0|D1|D2|D3] is omitted, the command sets the period of the square

waveform of the trigger output on the data line currently selected.

 The units supported by include s, ms and us. The default unit is s.

Return Format

The query returns a value from 0.000100 to 2.500000.

Example

:TRIG:OUT:PERI D1,0.005 /*Set the period of the square waveform of the trigger

output on D1 to 5ms*/

:TRIG:OUT:PERI? D1 /*Query the period of the square waveform of the

trigger output on D1 and the query returns 0.005000*/

Related

Command

:TRIGger:OUT:SIGNal

This manual is related to the following products: