Ac power specification, Environmental specifications – Grass Valley M-Series iVDR User Manual v.2.0.10 User Manual
Page 300
300
M-Series User Manual
20 April 2005
Appendix A Specifications
AC power specification
The M-Series iVDR AC power specification is shown in the following table.
WARNING: Always use a grounded outlet to supply power to the
system. Always use a power cable with a grounded plug, such as the one
supplied with the system.
Environmental specifications
Characteristic
Specification
Mains Input Voltage
100V to 240V auto-range, 50-60Hz
Power consumption
300W typical, 450W maximum
!
Characteristic
Specification
Ambient Temperature
Non-Operating
-40° to +60° C
Ambient Temperature
Operating
10° to +40° C
Relative Humidity
Operating 20% to 80% from -5
° to +45°C
Non-Operating 10% to 80% from -30
° to +60°C
Do not operate with visible moisture on the circuit boards
Operating Altitude
To 10,000 feet
IEC 950 compliant to 2000 meters
Storage Altitude
To 40,000 feet
Non-Operating
Mechanical Shock
Class 5 (30G) Thomson Grass Valley 001131500
Random Vibration
Operational: Class 6 Thomson Grass Valley 001131500
Non-Operational: Class 5 Thomson Grass Valley 001131500
Transportation
Thomson Grass Valley 001131500
Equipment Type
Information Technology
Equipment Class
Class 1
Installation Category
Category II Local level mains, appliances, portable equipment,
etc.
Pollution Degree
Level 2 operating environment, indoor use only.