beautypg.com

Ac power specification, Environmental specifications – Grass Valley M-Series iVDR User Manual v.2.0.10 User Manual

Page 300

background image

300

M-Series User Manual

20 April 2005

Appendix A Specifications

AC power specification

The M-Series iVDR AC power specification is shown in the following table.

WARNING: Always use a grounded outlet to supply power to the
system. Always use a power cable with a grounded plug, such as the one
supplied with the system.

Environmental specifications

Characteristic

Specification

Mains Input Voltage

100V to 240V auto-range, 50-60Hz

Power consumption

300W typical, 450W maximum

!

Characteristic

Specification

Ambient Temperature
Non-Operating

-40° to +60° C

Ambient Temperature
Operating

10° to +40° C

Relative Humidity

Operating 20% to 80% from -5

° to +45°C

Non-Operating 10% to 80% from -30

° to +60°C

Do not operate with visible moisture on the circuit boards

Operating Altitude

To 10,000 feet
IEC 950 compliant to 2000 meters

Storage Altitude

To 40,000 feet

Non-Operating
Mechanical Shock

Class 5 (30G) Thomson Grass Valley 001131500

Random Vibration

Operational: Class 6 Thomson Grass Valley 001131500
Non-Operational: Class 5 Thomson Grass Valley 001131500

Transportation

Thomson Grass Valley 001131500

Equipment Type

Information Technology

Equipment Class

Class 1

Installation Category

Category II Local level mains, appliances, portable equipment,
etc.

Pollution Degree

Level 2 operating environment, indoor use only.