beautypg.com

Csu line build out, Csu line build out -26, Igure – Verilink XEL XSP-100 SHARK IAP (9SA-USRS-9.0R1.02) Product Manual User Manual

Page 80: Wan t1

background image

Chapter 5: Graphical User Interface (GUI/WEB) Configuration Pages

Chapter 5-26

XEL P/N & Release: 9SA-USRS-9.0R1.02

SHARK™ IAD User's Guide

secondary WAN. Select the closest distance from the SHARK™ IAD to the
CSU or CPE attached to this module. See the Line Build Out section of the
WAN configuration page that is shown in Figure 21 for the possible selections.

CSU Line Build
Out

CSU build out is used to balance the 4-Wire T1 line going back to the Central
Office. Select the pad value needed to properly coordinate the transmit and
receive levels from the SHARK™ IAD at the NID or smart jack. Too hot of a
transmit signal level from the SHARK™ IAD at the receive in of the NID can
cause cross talking of the signals.

When you are satisfied with your WAN configuration choices, click on the save
button. This will save and load the new T1 configuration. The system will
return to the home page.

You have completed configuring the Transport functions of your SHARK™
IAD. Proceed to configure the Data transport selecting the config button of the
Router module.

Figure 21:

WAN T1 configuration page

WAN-1 Configuration

Alarm Reporting:

Disable

Enable

SF

ESF

SLC-96

Framing

Line Coding

AMI

B8ZS

Remote Loopback Option

In Band

ESF/FDL

DSX

Line Build Out

0-133 ft

133-266 ft

266-399 ft

399-533 ft 533-655 ft

-15 dB

-7.5 dB

-22.5 dB

Disable

Enable

Disable

Enable

CSU

CSU

CSU

CSU

DSX

DSX

DSX

DSX

0 dB