M
INIMUM SETUP
To begin configuring your SHARK™ IAD via the Ethernet port you only need the
following modules installed in your SHARK™ IAD. This chapter assumes that the
SHARK™ IAD has been installed and all cabling is intact.
Minimum
configuration for
Internet Access
• Router module.
• Power Supply Module.
• Cross Connect Module.
• WAN T1 Module.
Power source
The SHARK™ IAD operates on -48VDC. –48VDC can be supplied directly to the
power supply module or from the available AC Power supply. Refer to the
installation section of this User's Guide.
C
ONNECT TO YOUR
SHARK™ IAD
Attach a CAT 5 crossover cable from the Router's 10/100 BaseT port to your
computer's Network Interface Card (NIC). If the SHARK™ IAD is already
connected to your LAN's hub then a straight through CAT 5 cable can be used to
connect the computer, that you are using to configure the SHARK™ IAD, to the
hub.
W
ORKSTATION
S
ETUP
Because your workstation must be on the same subnet as the SHARK™ IAD, you
must access the workstation's operating system and enter the SHARK™ IAD's
default IP addresses into the workstation. These instructions will explain the steps
necessary to set up a PC running a Microsoft Windows™ 95, 98, or 2000 operating
system. Other operating systems will differ in HOW these tasks are performed but
not in WHAT needs to be done. Turn on your PC and continue with the following
steps:
1. Click on your PC's "My computer" Icon and click on the "Control Panel", or go to
your PC's "start" menu and select "Control Panel".
2. A. For Win95/98: click on "network". A network setup window will appear.
2. B. For Win2000: click on "network & dialup connection" icon. A network & dialup
connection box will appear.
3. A. For Win95/98: click on the "protocols" tab.
3. B. For Win2000: click on the local area connection icon.
4. A. For Win95/98: double click on the "TCP/IP" selection.
4. B. For Win2000: double click on the internet protocol (TCP/IP) selection.
5. A. For Win95/98: click on the "specify an IP address" option and enter the following
addresses in the appropriate fields.
5. B. For Win2000: Enter the following addresses in the appropriate fields.
– Enter in the unique TCP/IP address for this workstation i.e.:
192.168.1.1.
– Enter the SHARK™ IAD's default net mask:
255.255.255.0
in the subnet
mask field.
– Enter in the SHARK™ IAD's default LAN IP address:
192.168.1.254
into the
gateway field.
6.
DNS entry is not needed.
7. Be sure to not select the option for Proxy Settings.
8. Click on the ok button.
9.
For Win95/98: Restart your computer.