beautypg.com

Clear, Clear log, Clearstart – Verilink XEL XSP-100 SHARK IAP (9SA-USRS-9.0R1.02) Product Manual User Manual

Page 128: Coldstart, Configure, Console, Exit, Help or, Library, Library address

background image

Chapter 6: Using the Command Line Interface (CLI)

Chapter 6-12

XEL P/N & Release 9SA-USRS-9.0R1.02

SHARK™ IAD User’s Guide

ARP

arp nnn.nnn.nnn.nnn
Sends an Address Resolution Protocol (ARP) request to match the
nnn.nnn.nnn.nnn IP address to an Ethernet hardware address.

CLEAR

CLEAR LOG

Clears all current log entries.

CLEARSTART

clearstart [target] where target = [WAN1 | WAN2 | LAN1 | LAN2 | VOICE1
| VOICE2 | VOICE3 | XCONNECT |
ROUTER | SYSTEM]
Clears the configuration settings for the SHARK™ IAD module indicated,
which sets all parameters to their default values, and then restarts the module
indicated. You are asked to confirm the clear command. You must enter yes or
no.

Example:

SHARK010101000011> clearstart voice1
*** About to Clear Configuration and Restart the module Voice 1 ***
*** Do you wish to continue? (yes | no) no
Clearing configuration: ABORTED.

COLDSTART

coldstart [] [rtc] where:
target = [WAN1 | WAN2 | LAN1 | LAN2 | VOICE1 | VOICE2 | VOICE3 |
XCONNECT | ROUTER | SYSTEM]
'rtc' resets the real-time clock to 01/01/2000:00:00:00 (can only be used when
target = ROUTER or SYSTEM)
Restarts the module indicated without affecting the configuration of the
modules. The coldstart command does not require a yes or no verification, as
does the clearstart command.

CONFIGURE

See the configure section starting on page 6-21 of this chapter for a full list of all
configuration commands and their descriptions.

CONSOLE

Console
This command toggles the diagnostic output between the diagnostic log and the
shell session. At power-up the SHARK™ IAD defaults to the diagnostic log.
Only one shell session at a time may "own" the console output, and it must be
released before another session may redirect it.

E

XIT

Exits the SHARK™ IAD command line interface. Same as quit.

HELP OR

?

See "Using the CLI Help Facility" on page 6-11 of this chapter for a description
of the help command.

LIBRARY

library keyword argument parameters
Use "library" to install module firmware. Contact XEL's Technical Support at
1-800-544-6831 before attempting to perform software updates. XEL's technical
staff will coordinate all SHARK™ IAD software updates.

LIBRARY ADDRESS

library address []
Specify the IP address of the TFTP server to use for library installations. If no