beautypg.com

Module-mode, Jump to the right node, Set circuit cn: parameters – Verilink XEL XSP-100 SHARK IAP (9SA-USRS-9.0R1.02) Product Manual User Manual

Page 167: Impedance, Configure voice module -51, Module, Mode, Ump to the right node, Set circuit c n, Parameters

background image

Chapter 6: Using the Command Line Interface (CLI)

SHARK™ IAD User’s Guide

XEL P/N & Release 9SA-USRS-9.0R1.02

Chapter 6-51

you should use numbers in the range 2000-65535 when assigning new port
numbers to the SHARK™ IAD Telnet configuration interface.

CONFIGURE
VOICE MODULE

Begin configuration of the voice circuits by entering the configure VOICE1-3
subnode.
Enter the VOICE1-3 node as shown:

SHARK010101000011> CONFIG
(top)>> VOICE-1
(VOICE-1)>>

1 -Voice module 1 that is the module in the uppermost left slot in the unit.

2 - Voice module 2 that is the module in the center left slot in the unit.

3 - Voice module 3 which is the module in the lower left slot in the unit.

MODULE

-

MODE

(VOICE-x)>>

set module-mode param, where parameter = [ not-operational |

operational ]

not-operational - to deactivate the voice module
operational - to activate the voice module

J

UMP TO THE

RIGHT NODE

The command lines and parameters for the voice configuration can be lengthy.
The best way to tackle voice configuration is to jump to the lowest node
possible and then enter the set commands for each parameter or enter the set
command and enter the parameters line for line. These commands will be
shown jumping to the lowest node.

Enter the circuit cx node as follows:
x={1 | 2 .. through 8 }

(VOICE-1)>> circuit c1
...... [c1|c2|c3|c4|c5|c6|c7|c8]: circuit c1

(VOICE-1 circuit c1)>> set
circuit c1
impedance (600) [ 600 | 900 ]:
loop-length (0-999) [ 0-999 | 1000-1999 | 2000-2999 | 3000-3999 | 4000-49
99 | 5000-5999 | 6000-6999 | 7000Plus ]:
loop-wire-gauge (26) [ 26 | 24 | 22 ]:
alarm-processing (norm) [ norm | TMB ]:
state (standby) [ standby | active ]:
signaling (FXS) [ FXS | DPO | EMWink | EMWinkDelay | EMImmediate
| EMDelayDial ]:
(VOICE-1 circuit c1)>>

Specifies which circuit is to be configured for the specified voice module.

1 through 8 - Representing the eight circuits for module 1.

9 through 16 - Representing the eight circuits for module 2.

17 through 24 - Representing the eight circuits for module 3.

SET CIRCUIT C

N

:

(VOICE-1 circuit c1)>>

set parameter

parameter =[impedance | {loop-length | loop-wire-gauge when in Voice