Chapter 8- Maintenance/Diagnostics/Monitoring

SHARK™ IAD User's Guide

XEL P/N & Release: 9SA-USRS-9.0R1.02

Chapter 8-13

The digital loopback loops the received digital time slot (DS0) from the receive
data line to the transmit data line. Signal settings in the configurator do not
affect the loopback. The analog loopback is a full SLAC loopback which loops
the receive analog channel to the transmit analog channel and includes the
affects of the attenuation, impedance, and cable equalization settings.

Figure 10:

SHARK™ IAD Voice Loopbacks

Setting up a Voice
Loopback

Set up your loopback following these steps:
1. Select the module from the module pull down menu.
2. Select a type of loopback from the type pull down menu.
3. Select the circuit channel from the circuit pull down menu.
4. Click on the Exec button to begin the loopback.

Viewing all
Loopbacks

Click on the Show All button to view the Loopbacks that have been set up and
that may still be in process.

D

IAGNOSTICS

:

V

OICE

M

ODULE

T

ESTS

The SHARK™ IAD has the capability to monitor the signaling bits of any
circuit on the voice cards. Go to the Voice Module Tests control page by
clicking on the Diagnostics/Voice Module Tests buttons from the Maintenance
and Diagnostics page. Figure 11 shows the Voice Module Tests setup page with
all the options showing.

Digital Loop Back

FXS or FXO

9SA-FX_00-000

Cross Connect

Voice

Compensator

PCM Encoder/

Decoder

2-Wire

Port

SLIC

FXS or FXO

9SA-FX_00-000

Cross Connect

Voice

Compensator

PCM Encoder/

Decoder

Analog Loop Back

2-Wire

Port

SLIC