Chapter 6: Using the Command Line Interface (CLI)

SHARK™ IAD User’s Guide

XEL P/N & Release 9SA-USRS-9.0R1.02

Chapter 6-35

parameter in this case the password itself as shown here:

(ROUTER system)>> user-passwd
(ROUTER system user-passwd)>> set
user-passwd (""):test
(ROUTER system user-passwd)>>

A password is a minimum of six and as many as fifteen alphanumeric characters
of which one of them must be an alpha character. Passwords are case-sensitive
and leading, trailing, or embedded spaces. For example, if you assign a
password of "Shark1" to a SHARK™ IAD, you could not enter "SHARK1",
"Shark1", "ShaRk1", or "Shark1 " (with a trailing space) as an acceptable
password.

inactivity-timeout

Set inactivity-timeout x where: x = 0 to 10
This specifies the time duration for non-receipt of characters on the connected
Telnet session or the craft port session before a forced log out occures to that
session. The timeout is in minutes from 0 to 10 in increments of 1. A value of 0
results in the timer being disabled.

C

RAFT

S

ETUP

Use the craft-setup node to define enable/disable modem compatibility features.

SHARK010101000011> CONFIG
(top)>> ROUTER
(ROUTER)>> craft-setup
(ROUTER craft-setup)>>

Enters the craft setup node. See the following arguments and parameters to
enter the craft-setup parameters.

modem

modem y where: y = [ off | on ]
Enables or disables modem compatibility features: RTS/CTS handshaking and
modem initialization string.

init-string

Initial ASCII string sent to the external modem via the craft port at power

T

IME

D

IVISION

M

ULTIPLEXING

(TDM) S

ET UP

Use the tdm-setup node to define TDM parameters such as number of TDM
channels; the type of frame mode - frame relay, PPP, single-channel; and virtual
circuit parameters. You can configure up to two (2) TDM channels or data
pipes. Depending on the frame mode, each TDM data pipe can have up to four
(4) independent Virtual Circuit Connection (VCC).

SHARK010101000011> CONFIG
(top)>> ROUTER
(ROUTER)>> tdm-setup
(ROUTER tdm-setup)>>

Enters the tdm setup node. See the following arguments and parameters to
define the TDM channel.