Chapter 2: Installation

SHARK™ IAD User's Guide

XEL P/N & Release: 9SA-USRS-9.0R1.02

Chapter 2-5

XSP-100

A 3U

minimum

spacing

(5.25") must

be maintained

when multiple

units are

stacked in a

rack.

XSP-100

XSP-100

See detail for

bracket

installation on

each side

(2 places).

Configuration 2:

23" installation

Rotate bracket such that the short

side is flush against the unit.

Universal Mounting bracket

Side

of

unit

Configuration 1:

19" installation.

19" rack

Side View

Front View

23" rack

Side of

unit

Voice cables P/N

9SA-1208-t l n

T1 or Ethernet CAT5 Cable P/N: 9SA-12tt- t l n
Cross-over T1 or Ethernet CAT5 Cable P/N: 9SA-123t- t l n
Power cable or power source pigtail P/N 9SA-00tt-CBL
* t=type of cable ln=length of cable
See cable guide chapter for more cable details.

-48VDC

Frame gnd

Circuit gnd

-48VDC

Frame gnd

Circuit gnd

-48VDC

Frame gnd

Circuit gnd

FCC required
EMI Filters
installed on all
T1 transmission
CAT5 cable and
-48VDC power
lines. Filter xel
part number
180-A2003-01
comes with each
T1 and power
module.

Figure 3:

Multiple SHARK™ IADs shown Rack Mounted

See Figure 6 and
Figure 7 fo
r EMI
filter installation
details.