Description, Length, Pair twists – Verilink XEL XSP-100 SHARK IAP (9SA-USRS-9.0R1.02) Product Manual User Manual
Page 38: Function, Note, Model, Escription, Ength, Wists, Unction

Chapter 3: Cable Guide
Chapter 3-8
XEL P/N & Release: 9SA-USRS-9.0R1.02
SHARK™ IAD User's Guide
M
ODEL
:
9SA-1235-M06/M10/M20 T1
OR
10/100B
ASE
T (568B) CAT5
Description:
568B Category 5 Straight-Through cable for T1 or 10/100BaseT Ethernet
Length:
9SA-1235-M06
9SA-1235-M10
9SA-1235-M20
6 feet
10 feet
20 feet
Pair Twists:
1-2, 4-5, 3-6, 7-8
Function:
The 9SA-1235-Mxx series of cables are used to connect:
•
Terminal interface devices to the T1 interface modules of the SHARK™ IAD.
•
Ethernet connections to the 10/100 BaseT Ethernet ports of the SHARK™ IAD.
NOTE:
The EMI filter installation procedure shown in
cable is used to transport T1 signals.
RJ48(M)
RJ48(M)
Figure 5:
Model 9SA-1235-Mxx T1 or 10/100 BaseT (568B) CAT5 series cable diagram
CAT 5 cable transporting
T1 signals. Loop cable
through the filter as shown.
T1 connector that
connects to T1 module
9SA-T100-000
XEL part number 180-A2003-01 supplied with module 9SA-T100-000
2"
FCC requirements are that the EMI filter be
installed by the customer approximately 2" from
the end of the T1 input cable as shown.
Figure 6:
CAT 5 cable used for T1 transmission EMI filter installation
Table 3:
Model 9SA-1235-Mxx T1 or 10/100 BaseT (568B) CAT5 series cable Pinout
Signal Name when used as:
T1
10/100BaseT
Name
Direction
Name
Direction
RJ-48
(M)
Pin #
Twisted
Pair
RJ-48
(M)
Pin #
R
RCV
TX+
XMT
1
1
T
RCV
TX-
XMT
2
2
RX+
RCV
3
3
RX-
RCV
6
6
R1
XMT
4
4
T1
XMT
5
5
N/C
N/C
7
7
N/C
N/C
8
8