Model:9sa-00dc-cbl: -48dc power cable, Description, Length – Verilink XEL XSP-100 SHARK IAP (9SA-USRS-9.0R1.02) Product Manual User Manual
Page 40: Pair twists, Function, Note, Model, 9sa-00dc-cbl: -48dc power cable -10, Escription, Ength

Chapter 3: Cable Guide
Chapter 3-10
XEL P/N & Release: 9SA-USRS-9.0R1.02
SHARK™ IAD User's Guide
M
ODEL
:
9SA-00DC-CBL: -48DC P
OWER
C
ABLE
Description:
Four conductor stranded DC power cable with a Molex male connector to Ring
terminal pigtails.
Length:
10 feet
Pair Twists:
Function:
The 9SA-00DC-CBL cable is used to connect the SHARK™ IAD Power module
to a power distribution panel where -48 VDU is available. The cable is stranded
wire with pigtails at one end and a three pin Molex male connector that mates to
the SHARK™ IAD power module's front panel -48VDC power input connector
at the other end.
NOTE:
An FCC required EMI filter must be installed on this cable near the end that
connects to the SHARK™ IAD unit as shown in Figure 9.
Figure 8:
Model 9SA-00DC-CBL: -48 DC Power Cable with ring terminals
Fcc requirements are that the EMI filter be installed by the customer
approximately 2" to 3" from the end of the DC input cable as shown.
DC power cable from the AC External
Power supply 9SA-PWEX-000. Loop
cable as shown.
DCV Power connector that
connects to Power module
9SA-PW00-000
XEL part number 180-A2003-01 supplied with module 9SA-PW00-000
Figure 9:
Power module DCV power cable EMI filter installation
To site
Power
Distribution
Module's
terminal
blocks
1 foot
4 pin Male Molex connector
-48 D C input to the Power
Module's front faceplate input
connector.
-48 vdc
black
Frame Ground
white
-48 Return
red
cable shield
drain wire
green and yellow
V- GND V–
(-48V) (COM)
Cable End
9 feet