System voice mode, Note on network or cpe voice mode, E&m system settings – Verilink XEL XSP-100 SHARK IAP (9SA-USRS-9.0R1.02) Product Manual User Manual

Page 69: Digital cross connect, Ystem, Oice, Ave settings, Igure, Iming, Ource selection results

background image

Chapter 5: Graphical User Interface (GUI/WEB) Configuration Pages

SHARK™ IAD User's Guide

XEL P/N & Release: 9SA-USRS-9.0R1.02

Chapter 5-15

Table 6:

Timing source relationships

Timing source

XCON module

XC2T module

Results

internal

internal

All outbound T1 traffic is synchronized to the timing
source that is derived from the SHARK™ IAD's internal
clock source.

looped from WAN1

WAN-1

All outbound T1 traffic is synchronized to the timing
source that is derived from the WAN 1 network timing.

looped from WAN2

WAN-2

All outbound T1 traffic is synchronized to the timing
source that is derived from the WAN 2 network timing.

T1-1

All outbound T1 traffic is synchronized to the timing
source that is derived from the T1-1 network timing.

T1-2

All outbound T1 traffic is synchronized to the timing
source that is derived from the T1-2 network timing.

Timing source

selected

y

WAN1 or

y

WAN2 or

y

internal

Any sychronous

Serial data path

Synchronous

serial Traffic

WAN1

Network

traffic

WAN2

Network

traffic

T1 Module

LAN 1 or 2

PBX Traffic

all traffic is

Synchronized to

the selected

source

Figure 12:

Timing Source selection results

S

YSTEM

V

OICE

M

ODE

The Voice mode in the system menu (Figure 10 and Figure 11) controls whether
the SHARK™ IAD is in a Central Office (CO or network) environment or a
Customer Premise Equipment environment (CPE). Only a user who has logged
in using the system administrator password can change this mode. The
SHARK™ IAD is factory shipped in the NETWORK Mode.

Note on Network or
CPE Voice mode

To comply with specific FCC requirements the functionality of the Voice
modules has been separated into network and CPE modes.
Do not operate the SHARK™ IAD in the Network Voice mode while it is
installed as CPE equipment at a customer's premise.
Doing such is a violation of your SHARK™ IAD's FCC licensing

E&M System
Settings

The Voice system menu also configures the common E&M parameters for the
voice modules. NOTE: The following E&M settings apply to only and all
channels configured to an E&M signaling mode.
See Voice Configuration
Pages (page 5-57).