Chapter 5: Graphical User Interface (GUI/WEB) Configuration Pages

SHARK™ IAD User's Guide

XEL P/N & Release: 9SA-USRS-9.0R1.02

Chapter 5-25

A

LARM

R

EPORTING

Select the Alarm Reporting mode.

• Disable

Disables the reporting of alarms from this module. This does not

prevent the transmitting of a T1 signal or synchronizing of a received T1
signal.

• Enable

Allows the reporting of alarms from this module.

T1 F

RAMING

Select the T1 framing:

SF

Super Frame.

ESF

Extended Super Frame.

SLC-96

The SLC-96 option is compatible with SLC Mode 1, sometimes

known as SLC D1D, as outlined in standard TR08.

L

INE

C

ODING

Select the T1 Line coding:

AMI

Alternate Mark Inversion

B8ZS

Bipolar 8 Zero Substitution

R

EMOTE

L

OOPBACK

O

PTION

These parameters allow the user to enable the WAN module to respond to a
loopback code coming from the network side of the T1 interface. If the
appropriate option is enabled in this configuration page, the SHARK™ IAD will
respond to a loopback code sent from the T1. When the loopback detection is
turned off, the SHARK™ IAD will not respond to any loopback codes sent from
the network side of the T1.

Options are:

In Band:

Disable

Enable

ESF/DL

Disable

Enable

When the In Band is enabled and Line Build Out is set to DSX, the code of NI
can be detected. When the In Band is enabled and the Line Build Out is set to
CSU, the code of CSU can be detected. The codes of FDL Line, FDL Payload
and FDL Network can be detected when the ESF/DL is enabled and the Line
Build Out is set to either DSX or CSU.

L

INE

B

UILD

O

UT

The Line Build Out section of this page will only allow you to use either CSU or
DSX Line Build Out for each module. A CSU and a DSX Build out cannot be
selected at the same time for a module. The DSX and CSU interfaces may be
programmed independently for each module. If an external CSU is used
between a WAN or a T1 of the XC2T module and the NID, use one of the DSX
options in the WAN or XC2T card. If there is not an external CSU between the
NID and the WAN module, program the WAN module's CSU interface by
setting one of the CSU options. See the Line Build Out section of the WAN
configuration page shown in Figure 21 for the possible selections for the DSX
and CSU line Build Out.

DSX line Build Out

DSX line build out is used for pre-equalizing the 4-Wire T1 connection back
towards the CSU on the Central Office (CO) side or another CPE site using the