Jumpers jp4 and jp5, Configurations, Jumpers jp4 and jp5 -35 configurations -35 – Gasboy Atlas Start-up User Manual
Page 95: Figure 5-26, Pulse-out i/f (see

MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Page 5-35
Installing Atlas 9800 Pulse-out I/F with EM Totalizer Drive Board (M06587A001) Electronic and Electrical Components
When configured for Dual Channel, Dual Hose Pulse-out I/F, the P3 connector is used.
Jumpers JP4 and JP5
When this board is used in a model A or Q pump/dispenser or 9850K, jumpers JP4 and JP5 are
set to the Q/A position. When this board is used for all other K models except 9850K, these
jumpers must be in the K position.
Configurations
through
on
for different configurations.
Figure 5-26: Dual Channel, Single Hose Pulse-out I/F
Pulse Side 1
Side 1B Output (Green)
Side 1A Output (Red)
Side 1A Return (Black)
Side 1A Return (White)
Jumper Settings
Single Channel, Dual/Single
Hose Pulse-out I/F
(Default Setting)
Dual Channel, Single Hose
Pulse-out I/F
Dual Channel, Dual Hose
Pulse-out I/F
Wire Color
JP1 Position 1
JP2 Position 1
JP3 Open
JP1 Position 2
JP2 Position 2
JP3 Open
JP1 Position 2
JP2 Position 2
JP3 Jumpered
Black
No Connection
Side 1B Return
Side B Return
Blue**
No Connection
No Connection
Pulse Out Side 2A*
Brown
No Connection
No Connection
Pulse out Side 2A
Gray
No Connection
No Connection
Side 2B Return
Green
Pulse out Side 2
Pulse out Side 1B
Pulse out Side 1B
Amber
No Connection
No Connection
Pulse out Side 2B
Red
Pulse out Side 1
Pulse out Side 1A
Pulse out Side 1A
Violet**
No Connection
No Connection
Pulse Out Side 2B*
White
Common Return
Side 1A Return
Side A Return
Yellow
No Connection
No Connection
Side 2A Return
*Requires DC conduit M05683A004 Revision B or later.
**9850K models only.