MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Page 4-19
Programming 8800 Series Units
Pump Programming
Command Code 10: System Configuration
This multi-purpose code contains several sub codes called Function Codes (FC). Not all codes
are used for Atlas. If accessible, do not change other codes from their default values or the unit
may not work properly.
1
Press Enter after making selections.
2
Press 10.
3
Press Function #.
4
Press Configuration #.
Function Code 1: Unit Type
Defines the unit. It must be always set to 1 for Atlas.
1 = 1 product
2 = 2 product
Function Code 2: Money Decimal Point
Defines the money display format.
1 = xxxxx
2 = xxxx.x
3 = xxx.xx
4 = xxx.xxx
Function Code 3: Calculation PPU Decimal Point
Defines the PPU decimal point. Must use number 4 for US (required in U.S. as per W&M).
1 = xxxx
2 = xxx.x
3 = xx.xx
4 = x.xxx
Function Code 4: Displayed PPU Decimal Point
Configures the default value. Normally select 4 for US. If the displayed decimal point and
calculated decimal point are different, program FC 3 first.
1 = xxxx
2 = xxx.x
3 = xx.xx
4 = x.xxx
Function Code 5: STP Pre-start
Set to On for mechanical leak detectors or set to Off for most electronic line leak detectors.
Also, for self-contained pumping units, set to Off.
0 = Off
1 = On
Function Code 6: Beeper Option
Activates the beeper.
0 = Off
1 = On