Configuring 9800 Series
Pump Programming
Figure 4-6: Current Atlas 9800 CPU (M06333KXXXX)
Configuration Steps
This section provides steps for configuring the 9800 series (Electronic Commercial) for
various operating conditions.
Baud Rate
(JP1 on M06333KXXXX CPU and SW1-1 on Previous CPU)
This jumper/switch selects the baud rate for RS-485 communications. The Gasboy CFN
System and TopKAT Electronic System communicate at 9600 baud.
Baud Rate
JP1/SW1-1
1200
Jumpered/Closed
9600
Open
Mode
(JP2 on M06333KXXXX CPU and SW1-2 on Previous CPU)
This jumper/switch selects the mode in which the pump/dispenser operates. Set the mode to
“Online” if the pump/dispenser communicates through a RS-485 I/F (for example, to a
controlling Gasboy CFN, TopKAT Electronic System). Set the mode to “Standalone” for all
others including Pulse-out I/F configurations (for example, Pulse-out to a Gasboy Series 1000
FMS or TopKAT Mechanical System or non-Gasboy systems) or no controlling system.
Mode
JP2/SW1-2
Standalone
Jumpered/Closed
Online
Open