Removing/replacing lc meters, Coriolis meter, Refer to – Gasboy Atlas Start-up User Manual
Page 155
MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Page 6-35
Meters
Hydraulic/Mechanical Components
Removing/Replacing LC Meters
Note: This meter is used on Ultra-Hi models only.
To remove/replace the LC meter, proceed as follows:
1
Follow steps
.
2
Disconnect the pulser.
3
Remove the four bolts from the discharge casting.
4
Remove the four bolts on the inlet.
Note: Support the meter while removing the bolts.
5
Remove the meter.
6
Perform the required service on the meter.
7
Inspect and clean the inlet and discharge line mounting surfaces.
8
Install the new inlet and discharge gaskets.
9
Replace the meter.
10
Bolt the meter to the inlet.
11
Bolt the meter to the discharge casting.
12
Reconnect the pulser.
13
Follow the steps in
.
Coriolis Meter
The Coriolis Meter is a very precise mass flow meter that can be used to measure volume for
fluids of consistent density. It is extremely durable and has no sensitive components directly
exposed to fluids.
The stainless steel mass flow meter is used for DEF only. It contains no mechanical moving
parts and is extremely accurate (M10006A003).
Some important considerations for servicing the Coriolis Meter include the following:
• The meter electronic parts are serviceable by replacement. Typical error codes associated
with pulsers indicate symptoms of failure in the electronic parts. In case of such
symptoms, replace the electronic parts.
• The expensive meter electronics and hydraulics assembly can also be replaced.
• The meter hydraulics including the transducers are not serviceable. Replace the meter, if
these components are damaged.
• When servicing the electronics, you must reuse the purple chip from the previous meter or
the meter will not be properly adjusted. Use ESD protection when servicing the
electronics.