Gasboy Atlas Start-up User Manual
Page 169

MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Page 6-49
Hanging Hardware
Hydraulic/Mechanical Components
To replace the retriever reels, cables, and hose clamps, proceed as follows:
1
Install hose onto the pump/dispenser.
2
Allow hose to assume a natural coiled shape while holding the hose upright on the island.
3
If retriever reel does not have the cable, connect the cable to the reel.
4
Load the retriever reel to the required spring force.
5
Assemble the reel to the reel hanger.
6
Thread the cable from the reel through the cable grommet, and then through the hose clamp
lock ring.
7
Tie a knot and insert into the cable end.
8
Slide the cable end into the hose clamp lock ring. 1-inch hoses use metal clamps instead of
plastic hose clamps.
9
Install a retriever clamp at the top of the loop. Attach a hose clamp lock ring (cable end) to the
hose clamp. Use a cap screw and hex head nut to secure. Do not overtighten. Always use
appropriately-sized, padded, or contoured plastic clamps for hoses. Under-sized clamps will
damage the hose cover.
Figure 6-25: Replacing Retriever Reels, Cables, and Hose Clamps
10
With the retriever cable fully extended, ensure that there is some slack on the hose. Do not
allow coaxial hoses to touch the ground when retracted and hanging.