Gasboy Atlas Start-up User Manual
Page 48
Page 4-16
MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Pump Programming
Programming 8800 Series Units
Command Code 1: Program PPU
Manual programming of PPU, unit pricing. Pricing can also be downloaded through the
two-wire communication using the POS device.
To program the PPU, proceed as follows:
1
Press 1 and then press Enter.
2
Select the Side (1 or 2) and then press Enter.
3
Select the Grade and then press Enter.
4
Select the Price Level and then press Enter.
5
Enter the new PPU and then press Enter.
Note: Repeat steps
to
for the other Side, Grade, and Price Level.
Command Code 2: Program Two-wire/Standalone
To set the operation to Standalone mode (isolates sale control from the POS) or two-wire (unit
control through the POS), proceed as follows:
1
Press 2 and then press Enter.
2
Press the configuration number and then press Enter, where:
• 0 = Standalone mode
• 1 = Two-wire mode
• 2 = Pulse-out mode
Command Code 3: Program Allocation
Programming Volume Allocation basically sets the maximum sale size in units of measure (for
example, gallons).
To program the Volume Allocation, proceed as follows:
1
Press 3 and then press Enter.
2
Select the Side (1 or 2) and then press Enter.
3
Select the Hose/Grade and then press Enter.
4
Select the Allocation amount and then press Enter.
Note: Repeat steps
to
for the other Side, Hose, and Grade.