Error codes, Programming 8800 series units, Error codes -11 – Gasboy Atlas Start-up User Manual
Page 43: Programming 8800 series units -11
MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Page 4-11
Programming 8800 Series Units
Pump Programming
Error Codes
When operating the pump/dispenser, the 9800 series unit shows a two or three digit error
transaction code on the LCD display when transactions are terminated abnormally (that is,
other than turning the pump handle off).
The error codes are displayed for two seconds at the left of the LCD window, alternating with
a five-second display of the last sale amount. The display alternates between the two until a
new transaction begins. When an error occurs, note the error code and relay the information to
the system administrator.
The error codes are displayed for two seconds at the left of the LCD window, alternating with
a five second display of the last sale amount. The display alternates between the two until a
new transaction begins. In case of a 993 error, a new transaction will NOT start until the error
is cleared. When the 9800 series unit is in the Online mode, connected to a CFN or TopKAT,
transaction error codes are transmitted back to the system with the completed transaction data.
Note: Error Codes for the Atlas DEF units can be found in MDE-4331 Atlas Fuel Systems
Installation Manual.
Programming 8800 Series Units
For 8800 series units, the programming mode can only be entered when both sides of the
dispenser are in an idle mode, using the Manager Keypad. The nozzles must be in the nozzle
boots. Dispenser programming results in the unit being placed offline with regard to external
communications. Dispenser programming is started by pressing F1 on the Manager Keypad.
Following sub-sections describe general dispenser operation while in programming mode.
At each level, the PIN code must be entered. After you are in the third level, you can access
any programming process.
7
Pulser Adder
ON for 9840
ON for 9840K
8
ATC
ON for ATC ON, OFF for ATC OFF
ON for ATC ON, OFF for ATC
OFF
Code
Condition
01
RAM failure
02
ROM failure
55
Power failure
56
Pulser error
57
Timed out
58
Limit cutoff
59
Flow error meter 1 (9840 only)
60
Flow error meter 2 (9840 only)
99
Frozen error (9860 only)
993
Calibration error (9860 or 9870 only)
DIP Switch Settings
Switch
Number Switch Function
Settings for Existing and Model 9850K
Settings for Models 9840K,
9852K, 9853K