Pump Programming

Programming 8800 Series Units

Command Code 11: Grade Assignment (Perform this at Console)

Assigning Grades. Normally not used as grades must be programmed using the POS.

Command Code 12: Pump Program

This is also a multi-purpose code with sub-codes. Not all codes are used for Atlas. If
accessible, do not change other codes from their default value or the pump/dispenser may not
work properly.

To program the pump, proceed as follows:

1

Press 12.

2

Enter the Side #, where 1 = Side A, 2 = Side B.

3

Enter the Function Code (1-4).

4

Enter the Configuration Code.

Function Code 1: Two-wire Pump ID
Sets the two-wire ID that the POS uses for the pump/dispenser involved. Press Enter after
making selections.
1-16 = Choose a number between 1-16

Function Code 2: Cash/Credit at Pump
0 = No
2 = Yes

Function Code 3: Side Exists
0 = Does not exist
1 = Exists

Function Code 4: PPU Options
0 = Level 1 price bar displays the level sent by console
1 = Normal

Level 3 Programming

You must enter Level 1 and 2 before accessing Level 3 commands.

Level 1 - Press Fl, enter the 4-digit ID (default 2222), and then press Enter.
Level 2 - From Level 1, enter any Level 2 Command Code (10-12), enter the 4-digit ID

(default 1503), and then press Enter.

Level 3 - From Level 2, enter any Level 3 Command Code (13-17), enter the 4-digit ID

(default 1309), and then press Enter. Press F1 to exit any command code. Press F2 to
return to normal operation.

Command Code 13: PIN Code Change

Change PIN code. To change the PIN code, proceed as follows:

1

Enter 13.

2

Enter Level #1, 2, or 3.

3

Enter the new PIN code.
Note: The unit returns to Command Input Mode.