MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Pump Programming

Programming Overview

8800 Series Electronic Retail Units

The 8800 series Electronic Retail units perform with options such as sale control, totals
maintenance, preset, Automatic Temperature Compensation (ATC) functions,

electro-mechanical totalizers, and so on. External communication utilizes a proprietary

two-wire communication system, which is used or can be used by a host of Point of Sale
(POS)/controllers as manufactured by Gasboy, Gilbarco, Ruby Verifone

®

, Allied, and other

manufacturers. Interface devices for communication such as a Gilbarco PAM 1000 can also be
used to convert the two-wire communication to a usable format for other POS manufacturers
who cannot connect directly to the two-wire system.

Programming of the Electronic Retail units is accomplished using three levels of command
codes:

• Level 1 codes are potentially used by station personnel but also useful at times, during

service.

• Level 2 codes are higher level codes typically intended for the ASC in programming the

unit for desired operation.

• Level 3 codes are the highest level reserved for unit configuration and changing Personal

Identification Number (PIN) codes. All levels require entry of a PIN code before access.
These codes can be changed for station security. However, losing the codes will require a
master reset of the unit and reprogramming. Most codes have a default setting.

Figure 4-2: Electronic Retail Display

Atlas

TURN OFF ENGINE

Total Sale

Gallons

Total Sale