MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Pump Programming

Configuring 9800 Series

Leak Detect Delay
(JP3, JP4 on M06333KXXXX CPU and SW1-3, SW1-4 on Previous CPU)

These jumpers/switches select the delay time used by leak detectors in submersible pump
applications. The delay time is the period between the activation of the submersible pump and
activation of the slow flow valve. The delay time must be set according to the type of leak
detector installed on the submersible pump to allow a normal leak test for each transaction.
The delay time must be set to 0 seconds for suction pumps.

Delay Time JP3/SW1-3

JP4/SW1-4

0 seconds

Jumpered/Closed Jumpered/Closed

4 seconds

Jumpered/Closed Open

5 seconds

Open

Jumpered/Closed

6 seconds

Open

Open

Hose Pressurization
(JP5 on M06333KXXXX CPU and SW1-5 on Previous CPU)

For US Gallons (always in Hose Pressurization mode), this jumper/switch is ignored. This

jumper/switch is used to determine if hose pressurization is used. If enabled, the slow flow
valve is opened before reset is complete, to allow the hose to be pressurized before fuel
dispensing begins.

Pressurization JP5/SW1-5

Enabled

Jumpered/Closed

Disabled

Open

Authorization
(JP6 on M06333KXXXX CPU and SW1-6 on Previous CPU)

This jumper/switch allows activation or non-activation of the pump/dispenser from an external
source (for example, Pulse-out I/F configurations). When jumpered (closed), a 115/230 VAC
signal must be present on the Control Feed/AUTH line (for your model pump/dispenser, refer
to the wiring diagram) for pump activation to occur (required setting for Gasboy Series 1000,
TopKAT Mechanical and all non-Gasboy systems). When open, the Control Feed line signal is
ignored [normal setting for online mode communicating through an RS-485 I/F (TopKAT
Electronic System, CFN System) or standalone mode].

Authorization

JP6/SW1-6

Enabled

Jumpered/Closed

Disabled

Open

Note: For JP6 authorization, in standalone mode, the Auth Signal must be present to activate

the pump.