Page 5-19
PCAs
Electronic and Electrical Components
Figure 5-12: Atlas 9800 Pulse-out I/F with EM Totalizer Board (M06587A001)
Notes: 1) To be used with models calling out for Dual Channel, Dual Hose Pulse-out I/F (9850
Dual Hose requires M05683A004 Revision B or later).
2) M06587A001 Pulse-out I/F replaces the following 9800 Pump I/F Boards:
• Single Channel, Dual/Single Hose Pulse-out I/F Board, C06425.
• Dual Channel, Single Hose Pulse-out I/F Board, C06746.
3) For cable block diagram, refer to M05193.
PCA Connections and Cables
Connector #
Through Cable
To Assembly
At Connector #
P1 (4)
M05189A002
Field Wiring Main J-box
P2 (14)
Direct Connect
M05346A002 (115 VAC) or
M05346A004 (230 VAC) or
M06333KXXXX
P8 (14)
P802 (2)
M00455A002 Side A
P803 (2)
M00455A002 Side B
P804 (3)
M05108A001
C06372 or M12019A001
2 Connections Side A
2 Connections Side B
P1 (3)
M07588A00X
P2 (3)
Part Number
Where Used
M05158A001
To be used with all models (except 9850A/Q/K) calling out for Single
Channel, Dual/Single Hose Pulse-out I/F (see
M05158A002
To be used with all models (except 9850A/Q/K) calling out for Dual
Channel, Single Hose Pulse-out I/F (see
on
M05158A003
To be used with all models (except 9850A/Q/K) requiring only EM Totalizer,
no Pulse-out I/F.
Note: Models 9850A/Q/K can only use M06587A001, C06425, or C06746.