Programming 8700 series units, General programming details, Programming steps – Gasboy Atlas Start-up User Manual
Page 59: Programming 8700 series units -27

MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Page 4-27
Programming 8700 Series Units
Pump Programming
Programming 8700 Series Units
General Programming Details
The mechanical computer can be set for the price range and PPU (gallon/liter) dispensed.
Adjustments for volume of the product dispensed is accomplished at the meter calibration
adjustment wheel.
Note: 9100 series units do not require programming.
Figure 4-10: Variator Assembly for Mechanical Units
Totalizers
Note: The unit shown to the left is
an example of one type of
Totalizer. The example
shown is a Mechanical
Totalizer and is used only in
mechanical units.
Curved Panel Ends
Dollars/Cents
Gallons/Liters
PPU
Programming Steps
This section provides the programming steps for the 8700 Series unit.
Setting Calibration
Gasboy Atlas pumps and dispensers are tested for accurate measure at the factory. It is the
responsibility of the installer to check the unit for accuracy and make the required adjustments.
It is the owner’s responsibility to report this device to the local W&M authority for inspection
before putting the unit in service. For setting the calibration, refer to
Setting Prices
To set the prices, proceed as follows:
1
Unlock and remove the front panel. Repeat this procedure for the other side.
2
The variator section of the computer register(s) is exposed to allow for price changes. Slide the
variator cover of the computer register apart to expose the price range arms.