Gasboy Atlas Start-up User Manual
Page 40
Page 4-8
MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Pump Programming
Configuring 9800 Series
Pulse Output Rate Switches (If JP2 on M06333KXXXX CPU is Jumpered or SW1-2 on
Previous CPU is Closed)
When the pump/dispenser is connected to an external controlling equipment other than CFN
System, Fleet Plus System, or TopKAT Electronic System, that requires pulse output signals
(for example, Pulse-out I/F configuration interfacing with Gasboy Series 1000 and
non-Gasboy systems), the pulse signals are sent through the Pulse-out Interface Board. Setting
switches SW2-1 through SW2-3 configures the Pulse-out rate required by the monitoring
equipment. The Pulse-out rate represents the pulses per unit (gallon, liter, or imperial gallon).
SW2 may require to be sealed by a W&M paper seal if the unit is used for resale of the
product.
Pulse Rate
SW2-1
SW2-2
SW2-3
1:1
Closed
Closed
Closed
10:1
Open
Closed
Closed
100:1
Closed
Open
Closed
250:1
Open
Open
Closed
500:1
Closed
Closed
Open
None
Open
Closed
Open
None
Closed
Open
Open
None
Open
Open
Open
The maximum pulse output rate that can be achieved depends on the model of the
pump/dispenser and the unit of measure. Pulse output rate of 1000:1 is not supported.
Address
SW2-1
SW2-2
SW2-3
SW2-4
1
Closed
Closed
Closed
Closed
2
Open
Closed
Closed
Closed
3
Closed
Open
Closed
Closed
4
Open
Open
Closed
Closed
5
Closed
Closed
Open
Closed
6
Open
Closed
Open
Closed
7
Closed
Open
Open
Closed
8
Open
Open
Open
Closed
9
Closed
Closed
Closed
Open
10
Open
Closed
Closed
Open
11
Closed
Open
Closed
Open
12
Open
Open
Closed
Open
13
Closed
Closed
Open
Open
14
Open
Closed
Open
Open
15
Closed
Open
Open
Open
16
Open
Open
Open
Open