Page 5-48

MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Electronic and Electrical Components

Power Supplies

Main Power Supply (T19868-G1)

The Main Power Supply (T19868-G1) assembly contains the transformer, fuses, line filter, and
other components to provide unregulated 4.7 VAC backlights, 110 VAC valves and STP signal
relays, and 24 VAC to the Hydraulic Interface PCA. The Main Power Supply (T19868-G1)
uses a special voltage selector plug for establishing connections either to 115 VAC or 230
VAC systems.

Figure 5-41: Main Power Supply (T19868-G1)

24 VAC to T18994 P308 (2)

T9983-G1 Cable

To P302 (6)

LCD Main Display

J601 (3)

P604 (4)

T19983-G1 Cable

T19983-G1 Cable

P601

J604

J308

J302

Filter (Q10895-07)

Main Power Supply (T19868-G1)

Connector #

Through Cable

To Assembly

At Connector #

P601

Main Power Supply (T19868-G1)

Main Display (T17701 or T18981)

J601 (3)

J604

Main Power Supply (T19868-G1)

T19983 Cable

P604 (4)

J302

Main Power Supply (T19868-G1)

T19868 Cable

P302 (6)

J308

Main Power Supply (T19868-G1)

Pump Interface (T18994-G1)

P308 (2)