beautypg.com

General programming details, General programming details -12 – Gasboy Atlas Start-up User Manual

Page 44

background image

Page 4-12

MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Pump Programming

Programming 8800 Series Units

General Programming Details

Action

Cash Display

LSD in Volume Display

F1

1

2222

0000

1

ENTER
Repeats for Level 2

88888 Flashing

10

10

ENTER

2

1503

0000

2

ENTER
Repeats for Level 3

88888 Flashing

17

17

ENTER

3

1309

0000

3

ENTER

88888 Flashing

Notes: 1) It is important to note that each programming level utilizes a unique set of

programming codes. The reason for this is to allow room for future expansion of
programming features. Function codes within a command code begin at 1.

2) After the highest level security code has been entered, you can access all levels.

Entry into a command code will present data in either the DEFAULT format or last
programmed values for that command code. Only one command code and function

code/parameter may be programmed/changed at a time.

Figure 4-7

shows a PCA of the Gasboy 8800 Electronic System. For proper service, the

technician must be knowledgeable of the functions of components and how they relate to the
system.

Figure 4-7: Pump Controller (T20092)

AT_PumpPCA_controller

P206

P207

P208

P201

P204

P203

P202

P205

JP1