Page 4-12
MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Pump Programming
Programming 8800 Series Units
General Programming Details
Action
Cash Display
LSD in Volume Display
F1
1
2222
0000
1
ENTER
Repeats for Level 2
88888 Flashing
10
10
ENTER
2
1503
0000
2
ENTER
Repeats for Level 3
88888 Flashing
17
17
ENTER
3
1309
0000
3
ENTER
88888 Flashing
Notes: 1) It is important to note that each programming level utilizes a unique set of
programming codes. The reason for this is to allow room for future expansion of
programming features. Function codes within a command code begin at 1.
2) After the highest level security code has been entered, you can access all levels.
Entry into a command code will present data in either the DEFAULT format or last
programmed values for that command code. Only one command code and function
code/parameter may be programmed/changed at a time.
shows a PCA of the Gasboy 8800 Electronic System. For proper service, the
technician must be knowledgeable of the functions of components and how they relate to the
system.
Figure 4-7: Pump Controller (T20092)
AT_PumpPCA_controller
P206
P207
P208
P201
P204
P203
P202
P205
JP1