MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Page 6-61

Pumping Unit

Hydraulic/Mechanical Components

Sump for 9850K

Sumps do not require a periodic inspection, unless leaks or problems occur. Careful
troubleshooting will help determine whether to replace the entire sump or individual parts.

Service Tips

Read and follow all safety precautions as outlined in

“Read This First”

on

page 6-1

.

Sump overflows can be caused by:

• Defective sumps
• Air in pumping unit inlet lines
• Wrong sump type installed
• Internal sump float stuck

To determine possible causes, refer to

“Sump Overflows”

.

Above ground tanks must have a pressure regulator valve installed at the base of the pump.
Installation at other locations can cause flow or sump overflow problems. Ask Gasboy for the
valve type and follow the manufacturer’s instructions completely for installation.

Sump Overflows

Use the following table to help troubleshoot sump overflows:

If Sump Is Overflowing

Check These Items/Probable Cause

Only in bypass

With above ground tank

Anti-siphon valve

With tank less than 3-feet of
product

Replace pump

Sporadically in bypass

• Small air leak (check all connections).
• Missing or defective check valves
• Leaky piping

Only at start-up

• Missing or defective check valves
• Leaky piping

Only at full flow or both full flow and bypass

• Air leak (check all connections)
• Shared suction lines with missing or defective

check valve

• Leaky piping

If after checking the above probable causes, the sump continues to constantly overflow in full
flow or shortly after being placed in bypass, then replace the sump.