Start-up Procedures

Start-up Checklists

Page 3-2

MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Start-up Checklists

Installation Checklists

To ensure proper and safe operation of all equipment and to maintain warranty coverage, it is
required that the checklist be completed at this time. Many of the items on the list must have
been checked by the electrician already. Forms must be provided with each unit; if not, contact
the Gasboy Atlas Distributor. Make copies of the checklists for use in the field, to preserve
originals for future use.

Mechanical and Hydraulic Related Items Checklist

Item

Procedure

Refer To

Checked

1

Shear valves must be installed as per the valve manufacturer’s
recommendations. Shear point is ±0.75-inch of grade and properly
mounted.

2

Flexible pipes must not be used within the dispenser. However,

flexible pipes meeting local and state codes can be used below the
pump/dispenser, when allowed by regulatory authorities.

MDE-4333 Atlas Fuel Systems Site Prep Manual

3

Pumps (self-contained units) must have a vacuum actuated pressure
regulating valve to prevent positive pressure at the pump base, when
used with above ground tanks.

MDE-4333 Atlas Fuel Systems Site Prep Manual

4

Pumps require a check valve.

MDE-4333 Atlas Fuel Systems Site Prep Manual

5

Hose breakaways must be used and installed as per the manufacturer’s
recommendations. For units with retrievers, breakaways, and whip
hoses, hose breakaways must be attached to the nozzle end. For units
without retrievers, the hose breakaway is attached to the dispenser end.

Manufacturer’s specifications

6

The unit must be anchored to the island properly.

7

Vapor recovery piping at the pump/dispenser must have no traps or
sags.

8

Verify if there are correct nozzles, piping, and brand panels for each
grade.

Unit order specific

9

All code, regulatory agency, or customer specified safety warning signs,
labels, or decals have been installed.

As provided with and for unit

10

Long hose lengths beyond Gasboy Atlas recommendations must not be
used without special retrievers; for VaporVac

®

hoses, no more than

6 inches of hose length may rest on the ground when nozzle is resting in
boot. For balance vapor recovery, no portion of the hose may be on the
ground.

NFPA 30A

11

The unit is mounted using the proper quantity, size, and strength
mounting hardware.

12

The unit must pump fuel, as calibrated. All displays showing the
calibrated parameters must be accurate.

13

The pump must have a vertical lift of no more than 11 feet to deliver the
fuel.

14

The conduit used in the pump to deliver fuel must be of appropriate
diameter.

15

The distance of the pump from the under ground tank must not exceed
50 feet.