beautypg.com

Servicing pressure control valve (pcv), Servicing pressure control valve (pcv) -54 – Gasboy Atlas Start-up User Manual

Page 174

background image

Page 6-54

MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Hydraulic/Mechanical Components

Pumping Unit

Servicing Pressure Control Valve (PCV)

This section explains about servicing the pressure control valve.

Removing PCV

The purpose of the PCV is to apply a slight back pressure to the pumping unit, to prevent it
from pumping air through the meter (for example, during a dry tank situation). Meters will
meter air as well as fluid.

Excessive wear or a sticking PCV can cause improper pump performance, including flow loss,
excessive or low discharge pressure, or metering of air under a dry tank condition.

To remove a PCV, proceed as follows:

1

Drain the pumping unit. Refer to

“Draining GPU”

on

page 6-51

.

2

Remove the snap ring (see

Figure 6-29

).

Figure 6-29: PCV

3

Turn the valve cover outward or counterclockwise using a 16 mm socket wrench until it is
completely removed.
Note: The cover is held on by bolts and not screwed in.

4

Remove the spring and valve.

5

Remove the valve from the bore using needle nose pliers.