beautypg.com

Purging air from system, About purging system, Purging air from system -9 – Gasboy Atlas Start-up User Manual

Page 129: About purging system -9, Outlined in, Purging air from, System, Warning, Self-contained pumping units, Meter bolts

background image

MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Page 6-9

Purging Air from System

Hydraulic/Mechanical Components

Self-contained Pumping Units

Recommended Torque

Unit

in-lbs

Nm

Pump head (tightened in star pattern)

200

23

Strainer cover

150

17

Rear cover

200

23

Meter Bolts

Recommended Torque

Bolt (In Order)

in-lbs

Kg-meters

1

Cylinder cover gasket

130 ± 10

1.50 ± 0.12

2

Piston and connecting bar

35 ± 5

0.40 ± 0.06

3

Shaft seal cap

25 ± 5

0.30 ± 0.06

4

Lower bearing housing

75 ± 10

0.90 ± 0.12

5

Packing retainer

20 ± 5

0.25 ± 0.06

6

Body cover

130 ± 10

1.50 ± 0.12

Purging Air from System

• Wear eye protection. Residual pressure and entrapped fuel may still be present

and may drain or spray while removing the parts.

• Fire and explosion could result in severe injury or death.

• Test and close the involved shear valves. Shut off power to the unit.

• Remove the parts slowly. Collect fuel in approved containers.

• Clean up all spills promptly.

WARNING

About Purging System

Purge air from the hydraulic system properly. Failure to properly purge air from the system
can damage components and result in inaccurate calibration and fuel delivery. Purge air from
the system for new installations or when fluid containing parts of the hydraulic system are
serviced.