MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Page 4-9

Configuring 9800 Series

Pump Programming

Note: 9800 refers to models 9852, 9853, 9822, and 9823.

Unit of Measure

9800 Models 9840A/Q Models

9840K Models 9850 Models

US Gallons

500:1

500:1

500:1

100:1

Liters

100:1

100:1

10:1

10:1

Imperial Gallons

500:1

500:1

500:1

100:1

Note: If a valid Pulse-out rate is not selected, the M06333KXXXX CPU will not output pulses.

Leading zeros are always suppressed in the tens and hundreds place to the left of the decimal
point. In the Standalone mode, positions to the right of the decimal point are displayed based
on the pulse output rate and unit of measure selected as shown in the following table:

Timeout Switch (If JP2 on M06333KXXXX CPU is Jumpered or SW1-2 on Previous
CPU is Closed)
When the pump/dispenser is in the standalone mode including Pulse-out I/F configurations, it
will turn off an active hose outlet if it does not detect input pulses for 4 minutes and 15
seconds.

Timeout

SW2-4

Enabled

Closed

Disabled

Open

SW2-5 and SW2-6 - Unit of Measure Selection (Only on M06333KXXXX
CPU)

These two switches set the unit of measure (US gallons, liters, or Imperial gallons) that the
pump/dispenser will be using to meter fuel.

Unit of Measure

SW2-5

SW2-6

US Gallons

Closed

Closed

Liters

Open

Closed

Imperial Gallons

Closed

Open

NOT USED (default US Gallons) Open

Open

SW2-7 - Electro-mechanical Totalizer Enable (Only on M06333KXXXX
CPU)

This switch is only used on K model pumps/dispensers (excluding the 9850K model). When
closed (“On”), it enables the pump/dispenser to drive electro-mechanical totalizers used on
some K model pump. On A and Q models, this switch is ignored.

EM Totalizer

SW2-7

Enabled

Closed

Disabled

Open

Pulse Rate Gallons - US or Imperial

Liters and/or 9850

1:1

XXX.

XXXX.

10:1

XXX.X

XXXX.X

100:1

XXX.XX

XXXX.XX

250:1

XXX.XXX

XXXX.XX

500:1

XXX.XXX

XXXX.XX