MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Page 4-21

Programming 8800 Series Units

Pump Programming

Function Code 16: Beeper Timeout
Used in conjunction with FC 12 to turn beeper off after a programmed period of time.
0 = None
1 = 5 seconds
2 = 15 seconds
3 = 30 seconds
4 = 45 seconds
5 = 60 seconds
6 = 75 seconds
7 = 90 seconds
8 = 120 seconds

Function Code 17: Stop Control
Turns off one or both sides of the unit if the Stop option is pressed.
0 = Stop controls one side
1 = Stop controls two sides

Function Code 18: Zero Previous Transaction After Pump Handle Operation
Resets the last transaction after the pump handle is raised and the unit is authorized (required
for New Jersey, US).
0 = Zero after lamp test
1 = Zero before lamp test (Required for New Jersey)

Function Code 19: Lamp Test (Leak Detector Test)
It is not actually a lamp test; but it programs the amount of time the dispenser valves take to
open, after the handle is raised. Primarily used for dispensers with mechanical STP leak
detectors to allow the leak detector enough time to run its test.
1 = 1 second
2 = 2 seconds
3 = 3 seconds
4 = 4 seconds
5 = 5 seconds
6 = 6 seconds
7 = 7 seconds
8 = 8 seconds
9 = 9 seconds

Function Code 20: Programmable Pump Preset Value
Set to 1 for use with six-digit cash programming.
0 = Value X 1
1 = Value X 10

Function Code 21: PPU Blinking Option
0 = No PPU Blinking
1 = PPU Blinking

Function Code 22: Volume Decimal Point
0 = xxx.xxx
1 = xxxx. xx (export only)

Function Code 23: Program STP Control
0 = Off
1 = On