I.s barrier assembly atc (t19428-g1), Q10131-03 fuse, Electro-mechanical registers and totalizers – Gasboy Atlas Start-up User Manual
Page 110: About displays, Electro-mechanical registers and totalizers -50, About displays -50

Page 5-50
MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Electronic and Electrical Components
Electro-mechanical Registers and Totalizers
I.S Barrier Assembly ATC (T19428-G1)
shows the I.S Barrier Assembly ATC.
Figure 5-43: I.S Barrier Assembly ATC
Ground
J15 to R20147-G1
J201 (10) to P201 (10)
Q10131-03 Fuse
The size of the fuse used is 1.25 inches X 0.25 inches.
Electro-mechanical Registers and Totalizers
About Displays
Depending on the configuration, Atlas units may have electronic or mechanical registers or
totalizers. Totalizers provide a cumulative total similar to the odometer reading on a vehicle.
The display provides the customer with information about the total cost and total volume of
the fuel dispensed. PPU displays the PPU information to the customer.
Electro-mechanical Totalizer
An electro-mechanical totalizer is used for Electronic units. This replaces the cable-driven
accumulative totalizer for Electronic units. This totalizer is driven off the RS-485 and Pulse
Output Boards on the 9800 series and Hydraulic Interface Board on the 8800 series.
shows details of the Electro-mechanical Totalizer [M00455A003
(Retail units)]. In the electronic layout of Atlas pumps, there are two electronic totalizers, one
each on Side A and Side B. The sides are connected by the M04889A001 Cable through 4-pin
connectors J922A and J922B. The Electro-mechanical Totalizer for 9800 series is
M00455A002.