Solenoid valve and filter manifold, Solenoid valve and filter manifold -67, Warning – Gasboy Atlas Start-up User Manual
Page 187: About valve and filter manifolds, Recommended solenoid valve repair kits

MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Page 6-67
Valves
Hydraulic/Mechanical Components
Solenoid Valve and Filter Manifold
• Wear eye protection. Residual pressure and entrapped fuel may still be present
and may drain or spray while removing the parts.
• Fire and explosion could result in severe injury or death.
• Test and close the shear valves involved. Shut off power to the unit.
• Remove the parts slowly. Collect fuel in approved containers.
• Clean up all spills promptly.
WARNING
About Valve and Filter Manifolds
The Valve and Filter manifold connects to the meter inlet and provides filtration upstream of a
built-in 1-inch 2-stage solenoid valve. Filters must be selected and changed as per
. The valve diaphragm and coil are the serviceable parts.
Use Gasboy recommended kits for valve repair. Follow the instructions provided in the kit.
Recommended Solenoid Valve Repair Kits
Kit Description
Kit No
ASCO Diaphragm Repair Kit
M04607K010
ASCO Coil Replacement Kit - 110/120V M04607K012
ASCO Coil Replacement Kit - 220/240V M04607K013
The manifold also provides probe and thermowell ports for the ATC option.
There is also a no-valve manifold used on models that have a piping to satellite provision. This
provides filtration, but there is a separate valve downstream of the meter.
Figure 6-33: Valve and Filter Manifold
RTD Probe Port
Thermowell Port
ATC
Only
Inlet from Feedline
Filter and Strainer Adapter
Discharge to Meter
Diaphragm
Replacement
Coil Replacement
Valve and Filter Manifold
Models 8700, 8800, 9152/53, 9852/53
Filter Manifold - No Valve
Models 9140, 9840, 9153-S, 9853-S