MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Pump Programming

Programming 8800 Series Units

Function Code 8: Two-wire Display Blank Option
Activation of this code allows entering of a specific preset amount to be turned off on the
display at the dispenser using a remote POS device.
0 = Off
1 = On

Function Code 9: 5- or 6-digit Cash Display
Programs 5 or 6 digits of cash. POS must be set to the same.
0 = 5 Digit Money
1 = 6 Digit Money

Function Code 10: Decimal/Comma Mode
Programs display format.
0 = Decimal point
1 = Decimal point, comma

Function Code 11: Pre-select Timeout
The customer must make a decision (other than the default) within the programmed time or the
unit will be de-authorized.

Function Coda 12: Pump Timeout
After you begin dispensing of fuel, if the idle time exceeds the programmed time, the unit will
terminate the sale.
0 = None
1 = 5 seconds
2 = 15 seconds
3 = 30 seconds
4 = 45 seconds
5 = 60 seconds
6 = 75 seconds
7 = 90 seconds
8 = 120 seconds

Function Code 13: Slowdown
This determines the time for which the unit will be in a slowdown mode during a preset sale.
Setting it for too short time will result in you missing the target sale. Setting it for too long will
increase the time of completion the sale. This code is useful for preset problems.
0 = .070 gallons (.264 liters)
1 = .120 gallons (.454 liters)
2 = .170 gallons (.643 liters)
3 = .220 gallons (.833 liters)
4 = .270 gallons (1.02 liters)
5 = .320 gallons (1.21 liters)
6 = .370 gallons (1.40 liters)
7 = .420 gallons (1.59 liters)
8 = .470 gallons (1.78 liters)
9 = .520 gallons (1.97 liters)

Function Code 15: Zero PPU Pricing Option Enable
Allows dispensing of fuel with a “zero” PPU.
0 = Disabled
1 = Enabled