Page 6-3
Hydraulic and Mechanical Highlights
Hydraulic/Mechanical Components
Meter
The four-piston positive displacement flow through the CFT Meter increases resistance to fuel
contamination with a top inlet, bottom outlet, and self-cleaning central chamber. For
information on Coriolis Meter, refer to
on
Figure 6-2: CFT Meter
Assembled View of CFT Meter
1
Item #
Description
Current Part
Previous Part
Quantity
1
CFT Meter Assembly - Electronic Models
(Spare Parts item)
T20150-G5
-
(See Note 1)
CFT Meter Assembly - Mechanical Computer
Models, Gallons (Spare Parts item)
T20150-G6
-
(See Note 1)
CFT Meter Assembly - Mechanical Computer
Models, Liters (Spare Parts item)
T20150-G7
-
(See Note 1)
C+ Meter Plated Assembly, E85 Only
T19976-G5
(See Note 1)
• Meter Master Seal Service Kit Installation
(Reference Only)
K96618
-
(See Note 2)
• Meter Quad Ring Top Seal Replacement
Kit (Reference Only)
K35222
-
(See Note 3)
Notes:
1. CFT Meter is ordered only as an assembly.
2. MDE-3892 C+ Meter Master Seal Service Kit Installation provides information on how to install the Meter Master
Seal Service Kit (K96618). The kit provides materials and instructions for the complete change-out of all seals as
a major rebuild.
3. MDE-2188 Kits K35222 and K35222-01 Meter Quad Ring Top Seal Kit provides information on how to install the
K35222 Kit. The kit contains enough top seals to service ten (10) meters.