Page 4-24

MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Pump Programming

Programming 8800 Series Units

Function Code 6 = Authorize After Stop
0 = Disabled (Default)
1 = Enabled

Function Code 7 = PRC Restore Option Programming
0 = Disabled (Default)
1 = Enabled

Command Code 2 - To Program the Unit to the Pulse Output Mode

Function Code 0 = Standard Mode
Function Code 1 = Two-wire Mode
Function Code 2 = Pulse Output Mode

Option and Miscellaneous Programming/Data Acquisition

Special programming is involved in ATC and displaying Totals.

ATC Programming

At power-up, the units programmed with the ATC option will flash 104 before displaying
normal information. Units with the option, but not programmed for ATC will flash 100. To
program the ATC option, proceed as follows:

1

Turn On the programming switch on the ATC Controller Board.
Note: The dispenser must not be used during this programming and all pump handles must be

down or inactive.

2

Press 100 on the keypad and then press Enter.

• The money position showing fueling position selected will display 1.
• The volume position showing the fuel type selected will display 1, where:

1 = Gasoline
2 = Diesel

• The PPU position showing fuel density selected will display 730, where:

740 = Gasoline
840 = Diesel
730 = Default

3

Select the fuel type and press Enter.

4

The firmware sequence will sequence through each fueling position. Select the fuel type for
each position (diesel or gasoline).

5

Turn the programming switch on the ATC controller board to Off.

6

Press F2 to exit the ATC Programming mode.