beautypg.com

Pca connections and cables – Gasboy Atlas Start-up User Manual

Page 77

background image

MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Page 5-17

PCAs

Electronic and Electrical Components

PCA Connections and Cables

Connector #

Through Cable

To Assembly

At Connector #

P1 (6)

P/O M04850A008

P2 (6)

P/O M04850A008

P3 (4) Pulser 1


M05201A001(Cable) Pulser (8)

M04011B001 (cable)

Pulser Side A

P5 (4) Pulser 2

Pulser Side B

P4 (4)

M05105A001

Q12514-10 Pump Handle Switch A1

PH (B1) (4)

Q12514-10 Pump Handle Switch B1

PH (A1) (4)

P6 (2)

M05119A001

Q12514-13 Sensor

P7 (3)

Relay K1 (3) and (4)/Relay K2 (3) and (4)

P8 (14)

M06725A001

P2 (14) CPU

P9 (6) Not Used

P10 (3)

M05107A001

M07588A00X Atlas 9800 Power Supply
AC-DC

P1 (5)

P11 (26)

M05109A001

C06387 or M12158A00X P1 Side A and
P1 Side B

P1 (26)

P18 (3)

M00150A003 or M00150A004

ECAL Security Switches (DEF or E85
Only)

Figure 5-9: K-pump RS-485 with Totalizer

P802

P804

P803

P2

P1

P1

P802

P804

P803

M05248A001

M06725A001

Note: For cable block diagram, refer to M05193.