MDE-4334D Atlas™ Start-up and Service Manual · July 2013

Page 4-17

Programming 8800 Series Units

Pump Programming

Command Code 4: Program Manual Blank Display Cash/Volume Preset
Select

The Manual Blank and Five-button Preset is a dual use code that allows turning off displays
manually or is used to activate different preset modes depending on the options included with
the unit.

To program Manual Blank Display Cash/Volume Preset Select, proceed as follows:

1

Press 4 and then press Enter.

2

Select the Function Code (1 or 2) and then press Enter, where:

Function Code 1: Manual Blank Displays
Press the option code and then press Enter, where:
0 = Display Off
1 = Display On

Function Code 2: Cash/Volume Preset Select
Press the option code and then press Enter, where:
0 = No Five-button Preset or Programmable Pump Preset (PPP) installed
1 = Money Preset
2 = Volume Preset
3 = Incremental Preset

Command Code 5: Test Customer Programmable Preset

Test Programmable Customer Preset is a code that is used to initiate testing for the Five-button
Preset option if used.

To program the Test Programmable Customer Preset, proceed as follows:

1

Press 5 and then press Enter.

2

Select the Configuration and then press Enter, where:
0 = STOP Test/Program
1 = START Test/Program

Depending on the preset option, the type testing will convey the following when you press the
preset buttons:
Five-button Preset (Non-customer Programmable Preset)
Press Enter after making selections, where:
1 = Program Button 1 (Default 1)
2 = Program Button 2 (Default 5)
3 = Program Button 3 (Default 10)
4 = Program Button 4 (Default 15)
Incremental Preset (Non-customer Programmable Preset)
Press Enter after making selections, where:
1 = Program Button 1 (Default 1) Money
2 = Program Button 2 (Default 5) Money
3 = Program Button 3 (Default 10) Money
4 = Program Button 1 (Default 1) Volume
5 = Program Button 2 (Default 5) Volume
6 = Program Button 3 (Default 10) Volume

After the test is complete, follow programming steps to setup.